Cause
Fuser high temp error.
Resolution
- Power the machine OFF from the main switch leaving the sub switch ON.
- Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
To reset a fuser abnormality code, perform the following:
Then you will need to follow below to reset the dip switch on the machine.
- Power the machine OFF from the main switch leaving the sub switch ON.
- Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
- Press [03 System Setting] on the touchscreen.
- Press [01 Software SW setting] on the touchscreen.
- Press the left up-arrow, which is displayed on the touchscreen, 2 times. The number displayed above the up-arrow will change to 03.
- Select the bit number of switch 1, using the right up-arrow, 03-1 will be indicated.
- Turn the setting to OFF
- Press the [Return] key, which is displayed on the touchscreen.
- Exit Service mode to return to normal operation
C-3501, C-3502, C-3503, C-3504, C-3505, C-3506, C-3507, C-3508, C-3509, C-3801, C-3802, C-3803, C-3804, C-3805, C-3806C-3901, C-3902, C-3903, C-3904, C-3905, C-3906, C-3907, C-3908, C-3909, C-3910,C-3911, C-3912, C-3913, C-3914, C-3915, C-3916