12 Dec 2017 10:38 am    

Cause

Fuser high temp error.

Resolution

  1. Power the machine OFF from the main switch leaving the sub switch ON.
  2. Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
    To reset a fuser abnormality code, perform the following:
    Then you will need to follow below to reset the dip switch on the machine.
  • Power the machine OFF from the main switch leaving the sub switch ON.
  • Turn main power switch ON while pressing the Utility/Counter key. Keep holding it till the comes up in Service mode.
  • Press [03 System Setting] on the touchscreen.
  • Press [01 Software SW setting] on the touchscreen.
  • Press the left up-arrow, which is displayed on the touchscreen, 2 times. The number displayed above the up-arrow will change to 03.
  • Select the bit number of switch 1, using the right up-arrow, 03-1 will be indicated.
  • Turn the setting to OFF
  • Press the [Return] key, which is displayed on the touchscreen.
  • Exit Service mode to return to normal operation